Centrio 3C3 on suorituskykyinen turvatun sähkönsaannin laite liiketoiminnalle kriittisten laitteiden suojaksi.
  • Virtakapasiteetti 16 kW / 20kva(384vdc), with super charger board without batteries 3/3 phase
  • ilman akkuja,
  • LCD screen
  • Tulojännite Input: 3 phase,
    Connection 3-Phase + N + G
    Rectifier Type IGBT-based Controlled PFC
    Input Voltage 380(-45%~ +25%)VAC(when input voltage<75%, output power derating is required)
    Input Frequency 50 or 60 Hz (Accepted from 40 to 70Hz)
    Input Current THD 3%
    Input Power Factor ≥0.99
    Bypass Voltage 380(-15%~ +15%)VAC
  • Lähtöjännite Output: 3 phase

    Inverter Type IGBT-based
    Output Voltage 380/400/415VAC
    Output Frequency 50Hz/60Hz±8%track bypass frequency input ;when input frequency exceeds ±8% or under the mode of battery power supply, frequency output should be±0.1%of nominal
    Output Voltage THD 1% (max) Max.Load Crest Factor 3:1
    Transient Volt.Resp 10ms to recover ± 5% of Nominal Voltage for 0% to 100% or 100% to 0% step load
    Max.Leading PF Load Up to 0.9
    Overload Capability ≥10min 110% ≥1min 125%
  • Dimension(W×D×H)(mm×mm×mm) 771*558*1169
  • Backup time 5-15 min
  • The excellent performance. IGBT based, high frequency rectifier and inverter design to achieve up to 93% - 94% efficiency(Mains mode and Battery mode), and low input current THD(<3%) ECO mode to achieve up to 98% efficiency for energy saving
  • High performance DSP processor. The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability
  • Flexible battery arrangement. Flexible arrangement of the amount of accumulators in each battery (32, 30, or 28) can be achieved through the parameter resetting in the Centrio 3C3 series UPS, which effectively solves the question that the damage of some individual cell may influence the life of the whole battery unit by eliminating the damaged ones from the unit in the process of using UPS. N + X parallel redundancy (compatible to battery share in the parallel mode) The advanced controlling strategy is adopted to save the customer's investment by sharing a battery unit in the parallel re- dundancy mode
  • Excellent performance in indus-trial environment protection Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard the UPS's security of operation in bad environment.