Description
Economizer SET 200
Heat exchanger 8 m2 AISI 321
All heaters are pressure tested to 5 bar. Max. operating pressure is 1 - 2 bar.
The exchangers can be clean by pressure washer
Smoke flue and condensate extraction are not included in the delivery order
The basic version is without insulation. It is available as an accessory.
Height 2000 mm (without flue connection and cone)
Dimensions 600 x 600 mm
Recommendation - flue diameter: max 600 mm
Max operating pressure: 5 bar
Working pressure: 1 - 2 bar
Heat output 15 - 40 kW and more if the exhaust gas temperature is more than 250C
Recommendation for boiler boiler - 50 - 200 kW
Material: stainless steel AISI321
4 heat exchangers
Volume 10 l
Flow 30 l/min
The heat exchange area is 8 m2
Flue gas pressure loss 1 - 3 PA
in Fig. 3 - Opened Demo, Fig. 4 - Heat Exchanger rst AISI321
Features
- Model: SET200
- Shipping Weight: 150lbs
- Manufactured by: Suomen EnergiaTehdas Oy