900 L with 1 coil
900 L Thermal Storage Tank – DHW Coil
Thermal storage tanks are designed to function as part of a closed-loop hydronic heating system. The tank is connected to a heating boiler.
Maximum operating pressure in the coil: 10 bar
Maximum temperature: 95°C
Heat exchanger coil surface area: 1.34 m²; upper stainless steel heat exchanger for domestic hot water (DHW): 22 kW – 1.34 m²
Heat exchanger volume: 4.3 L
Heat exchanger pipe length: 10 m
Maximum operating temperature: 95°C
Maximum operating pressure: [see specifications]
Connections: DN 20
Tank temperature: 63°C
Inlet temperature (cold): 15°C
Outlet temperature (hot): 45°C
Temperature difference (ΔT): 30°C
Flow rate: 1.05 m³/h
Output: 38–79 kW
Maximum operating pressure (tank): 3 bar
Maximum operating pressure (heat exchanger): 10 bar
Insulation: 50 mm, with a 1 mm plastic outer casing
The insulation can be installed quickly and easily on-site.
Note! Shipping tables are based on chargeable weight!