  • Model: EK08Light
  • Shipping Weight: 41 lbs

Starting at: €1,011.08

Please Choose:

stock electricity searching






D accessories




Electric boiler EK 08 Light
Highly efficient boiler EK 08 Light is designed for economical heating of buildings, flats, low-energy houses and small recreational facilities with heat loss up to 7,5kW. It can be also used as a back up source for modern heating system with a heat pump, solar or fire place insert. Automatic power control ensures economical boiler operation.
The boiler is controlled by electronics and is also equipped with a pump with 5m displacement. The heater body consists of 3 heating elements, each with an output of 2,5kW, the rod rotation increases the life of the boiler. With using non direct tray the boiler can be used for domestic hot water supply by three-way valve already installed in the boiler.
EK 08 Light can be controlled by a room thermostat. It is not equipped with weather-compensated control, expansion vessel and a GSM modul. It features minimum dimensions, quit and economical operation. It can save your energy costs and ensure you comfy and care heating.
Features of EK 08 Light
  • Comfort settings and control through multifunctional LCD
  • High efficiency up to 99%
  • Small dimensions, modern design
  • Silent running
  • Dynamics of heating rod flow (PI regulation), energy savings
  • do not allow water overheating above the set temperature
  • Heating rods rotation increases the life of the boiler
  • Continuous power regulation as from 2,5kW with switching of heating rods gradually - prolonged boiler service life.
  • Switching boiler system by ripple through terminal room thermostat
  • Protection and unblocking functions:
  • three-way valve protection, pump protection (adjustable time run-out and temperature run-out period)
  • antifreeze protection
  • Selection of the flow temperature hysteresis
  • Possibility to connect DHW accumulator
  • Function of preferential DHW heating
  • Information on pressure in heating system through manometer
  • Standby mode
  • Automatic venting
  • 3 heating systems:
    for water heating only
    with room thermostat only
    with room thermostat and DHW preparation
  • Possibility of cascade arrangement